RTS KP95 User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 90
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
12
Advant Controller 31 / Issued: 03.99
Hardware 07 KP 90 R303
8 .1
1.7.5 Mechanical data
Mounting on DIN rail in accordance with DIN EN 50022–35, 15 mm deep.
The DIN rail is located in the middle between the upper
and the lower edges of the module.
Fastening by screws using 4 M4 screws.
Width x height x depth 140 x 120 x 85 mm
Wiring method by removable terminal blocks with screw-type
terminals, max. 2.5 mm
2
Weight 450 g
Dimensions for mounting see the following drawing
5
94
94
120
65
130
140
65
111
75
20
1.7.6 Mounting hints
Mounting position vertical, terminals above and below
Cooling The natural convection cooling must not be hindered by
cable ducts or other material mounted in the switch-
gear cabinet.
The device is 85 mm deep. The interface connectors RCOM and CONSOLE are set deeper so that the mount-
ing depth required does not become any larger even with detachable interface cables. If, however, a DIN rail is
used, the mounting depth is increased by the overall depth of the rail.
Fig. 13: Dimensions of the Communications module 07 KP 90 R303,
front view, the dimensions for assembly bore holes are printed in bold