2 INSTALLATION
2.1 GENERAL
Installation consists of the following general steps:
1. Unpack and inspect the equipment.
2. Check that the factory default jumper positions and
level settings are appropriate for your application and
make any required changes. (The defaults are
virtually always acceptable.)
3. Set the back panel DIP switches.
4. Mount the keypanel and any expansion panels in an
equipment rack or bay.
5. Connect the keypanel and any expansion panels.
6. Power up the equipment and check operation.
7. Program the keypanel using the intercom system
configuration software (ADAMedit or ZEUSedit).
2.2 UNPACKING AND INSPECTION
As soon as possible after receipt, inspect the container(s)
and contents for physical damage that may have occurred
in shipping. If damage has occurred, immediately (within
24 hours of receipt of equipment) contact the carrier in-
volved and file a claim. Save all packing materials, and
request an immediate inspection by the carrier’s insurance
claims agent.
There should be one power cord for each keypanel and
one gooseneck microphone for each keypanel ordered
with a microphone. There should be one power cord and
one interconnect cable for each expansion panel.
For information about returns to RTS, refer to the
front of this manual.
2.3 CHECKING THE FACTORY JUMPER AND
LEVEL SETTINGS
There are several internal jumpers and level adjustments
which can be changed to modify the keypanel operation
and audio input/output levels. These have been set to meet
the requirements of most typical situations. However, if
you wish to review these settings prior to installation, re-
fer to “Electrical Adjustments”, page
12.
2.4 DIP SWITCH SETTINGS
The DIP switches are located on the back of the keypanel.
The switch settings are summarized in Table
1 and are de-
scribed in the following paragraphs.
Important: Any time you change the DIP switch
settings you must turn the power off-then-on to reset.
2.4.1 Logical Keypanel ID Selection
DIP switches 4-7 set the logical keypanel ID, which
uniquely identifies the keypanel in the intercom system.
Zeus Intercom Systems: The logical keypanel ID’s are
the numbers ID1 through ID8 printed on the back panel of
the Zeus frame next to the keypanel connectors. (The
numbers repeat for every group of 8 connectors.) As you
connect each keypanel to a connector, use the number
printed next to that connector to set the ID. For example,
if you connect a keypanel to a connector numbered ID1,
refer to Table
1 and set DIP switches 4 through 7 to select
ID1.
8 Installation Instructions, KP95-0 Keypanel
DIP
Switch
Description Settings
(X=Don’t care)
1 Not used X
2 Not used X
3 Not used X
ID SW 4 SW 5 SW 6 SW 7
4-7
Logical keypanel
ID select.
1 Close Open Open Open
2 Open Close Open Open
3 Close Close Open Open
4 Open Open Close Open
5 Close Open Close Open
6 Open Close Close Open
7 Close Close Close Open
8 Open Open Open Close
8 Baud rate select Open: 9600 baud
Closed: 76.8 kbaud (DO NOT USE!)
Table 1. DIP Switch Summary
Page view 7